Renewable Energy - 5 Step Design Process

» Click to Download Array Sizing Load Worksheet Calculations
(20KB, PDF File Format)
» Step 3 - Size the Solar Array, Wind Generator, and/or Hydro Turbine
The size of the Solar Array, Wind Generator, and/or Hydro Turbine is determined by the Load Analysis and the Load Correction Factor (in order to compensate for efficiency losses in the system). Sundance suggests a professional System Sizing.

Grid-Tied Array Sizing

  • Refer to a Solar Insolation Chart to determine the average peak sun hours per day for your location
    • For example, the average in North Carolina is 4.5 peak sun hours
  • To calculate the sustem size (AC Watts) to provide 100% of your electricity you divide your average electricity use by the average sun hours per day.
    • For example, if the average daily electricity use is 30kWh, and the site is in NC, the system size would be: 30kWh/4.5h=6.6kW AC
  • Divide the System AC Watts by the Watt Rating of the PV Module
  • Divide by the Inverter Efficiency (Usually 94%) to get the Total Number of Modules Required
    • For example, 6.6 k/W AC / 120W (Kyocera KC120) / .94 = 58 Modules

 

 

 

 

 

 

 

 